Part Number Hot Search : 
24S15 200BG 3B20D0 FLM10 TBB1004 D200R D68H8D10 092315
Product Description
Full Text Search
 

To Download TFS120C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 tfs 120C.doc
Version 1.0
06.01.02
VI TELEFILTER
Filter specification
TFS 120 C
1/4
1. Measurement condition Package, pin connection and 50 matching network Ambient temperature TA: 23 C Input power level: 0 dBm for input: 1270 -11,7 pF. Typical terminating impedances in fN: for output: 4330 -2,9 pF.
(see sheet 2.)
2. Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 120C is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The nominal frequence fN is fixed at 120,0 MHz without tolerance or limit. The reference frequence fc is the arithmetic mean value of the upper and lower frequencies at the 40 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency response of the filter in the operating temperature range.
Data Insertion loss (Reference level) ae Nominal frequency fN Centre frequency fc at ambient temperature ( fCAT ) Pass band Amplitude ripple (p-p): fN ... fN 4,45 MHz Amplitude ripple (p-p): fN ... fN 4,50 MHz Bandwidth at ambient temperature : 1,0 dB - band width 1,5 dB - band width 3 dB - band width 40 dB - band width Relative attenuation arel fN fN 4,5 MHz MHz fN 25 MHz fN 5 MHz fN - 25 MHz fN - 120 MHz fN + 300 MHz fN + 25 Group delay Group delay ripple in pass band (p-p): Triple transit attenuation compared to main signal Crosstalk Frequency inversion temperature ( To ) Temperature coefficient of frequency ( Tcf ) Frequency deviation of fc over temperature T : *) Operating temperature range Storage temperature range Input power level Permissible DC voltage VDC Permissible DC voltage Vpp
typ. value 27 0,5 dB 120,01 MHz 0,6 8,98 9,07 9,15 9,90 42...70 70 70 3,03 120 60 MHz MHz MHz MHz dB
tolerance / limit max 33 dB 120,0 MHz fN - 4,5 MHz ... fN + 4,5...MHz max 3,0 dB
dB dB dB s ns dB
max 3 min 40
dB dB
max 6 max 400
s ns
55...67 dB -5 C -0,036 ppm/K fc(Hz) = Tcf(ppm/K) x (T - To) x fTo(MHz) -20 C ... + 75 C - 40 C ... + 85 C max. + 10 12 10
-
dBm V V
*) fTo is reference frequence fc at frequency inversion temperature (To )
Generated:
Wadim P. Dunzow
Checked/Approved:
Dr. Bert Wall
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs 120C.doc
Version 1.0
06.01.02
VI TELEFILTER
3. Package
Filter specification
TFS 120 C
2/4
TFD 125 TFS 120 C tft L6 tft H9
Pin 1 Pin 14 Pin 8 Pin 7 Pin 2,9
Input Input RF Return Output Output RF Return Pakage Ground
4. 50 matching network: 12 7
L1 L3
14 9 8
C1
C2 L2
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
tfs 120C.doc
Version 1.0
06.01.02
VI TELEFILTER Air reflow temperature conditions
Filter specification
TFS 120 C
3/4
1st and 2nd air reflow profile
Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C
Chip-mount air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com
Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information


▲Up To Search▲   

 
Price & Availability of TFS120C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X